Gold Member Since 2016
Pego Group (HK) Co., Limited

Test Finger, IEC Test Finger, Standard Test Finger manufacturer / supplier in China, offering IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate, Power Supply Swivel Flexing Testing Machine IEC60335 Clause 11.101, UL498 Gauges Used for Testing American Plug and Socket-Outlet and so on.

(/ )

Supplier Homepage Product Probes for Verification IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate

IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate

FOB Price: US $210-260 / piece
Min. Order: 1 piece
Min. Order FOB Price
1 piece US $210-260/ piece
Get Latest Price
Port: Shenzhen, China
Production Capacity: 100 Sets/Month
Payment Terms: T/T, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: PG-2B
  • Material: Delrin and Steel
  • Certificate: CNAS and ILAC-MRA Calibration Certificate
  • Condition: New
  • Service: Customization
  • Transport Package: Carton
  • Origin: China
  • Standard: IEC60529, IEC61032, IEC60065, IEC60335
  • IP Code: IP2X
  • Warranty: 1 Year
  • Lead Time: 3 Days
  • Trademark: Pego Tester
  • Specification: metal, insulating meaterial
  • HS Code: 9024900000
Product Description
IEC60335 60065 Standard Jointed IEC Test Finger
1. Introduction
The standard jointed iec test finger is design according to IEC61032 figure 2, meet the requirements of UL507, UL1278 figure 8 and EN60529 figure 2. This probe is intended to verify the basic protection against access to hazardous parts. It is used to verify the protection against access with finger.
 IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate

2. Specification
Diameter of dactylogryposis:12mmLength of dactylogryposis:80mm
Diameter of baffle:50mmLength of baffle:100mm
Material: Insulating material (baffle and handle), metal(dactylogryposis)
Note: 10±1N thruster for optional

3. Relative Products
Test Probe A for IP1X Testing
Introduction:
Designed according to IEC61032 fig.1, and meet the requirements of IEC60529 regarding IP1X testing and IEC60065. This probe is intended to verify the protection of persons against access to hazardous parts. It is also used to verify the protection against access with the back of the hand.
IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate
Specification:
Diameter of test sphere:50mmDiameter of baffle:50mm
Thickness of baffle:4mmDiameter of handle:10mm
Length of handle:100mm
Material: insulating material (handle and baffle), metal (test sphere)

Test Probe B for IP2X testing
Introduction:
Design according to IEC61032 figure 2, meet the requirements of UL507, UL1278 figure 8 and EN60529 figure 2. This probe is intended to verify the basic protection against access to hazardous parts. It is used to verify the protection against access with finger.
IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate

 Specification:
Diameter of dactylogryposis:12mmLength of dactylogryposis:80mm
Diameter of baffle:50mmLength of baffle:100mm
Material: Insulating material (baffle and handle), metal(dactylogryposis)

Test probe C for IP3X testing
Introduction:
Designed according to IC61032 figure 3, meet the requirements of IEC60529-IP3, IEC60065,IEC60598 and etc. This rod is intended to verify the protection of persons against access to hazardous parts. It is used to verify protection against access with a tool.
IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate
Specification:
Length of test rod:100mmDiameter of test rod:2.5mm
Dimater of stop sphere:35mmDiameter of handle:10mm
Length of handle:100mm
Material: Insulating material (handle, sphere), metal (test rod)

Test Probe D for IP4X testing
Introduction:
Designed according to IEC61032 figure 4, meet the requirements of IEC60529-IP3,IEC60065,IEC60598 and etc.   This wire is intended to verify the protection of persons against access to hazardous parts. It is used to verify the protection against access with a wire.
IEC61032 Jointed Test Finger Probe with CNAS Calibration Certificate

Specification:
Length of test wire:100mmDiameter of test wire:1mm
Diameter of stop sphere:35mmDiamter of handle:10mm
Length of handle:100mm  
Material: Insulation material (handle, stop sphere), metal (test wire)

Test Probe 1 (500g steel sphere)
Introduction:
Designed according to IEC61032 figure 5, meet the requirement of IEC60529-IP. The diameter of the sphere is 50mm+0.05, sphere is intended to verify the degree of protection of enclosures against ingress of solid foreign objects have a diameter of 50mm or greater. 
Specification:
Diameter of sphere: 50mm+0.05
Weight of the sphere:500g
Material: steel